WF 3144 – Programmable Resistor Module
The WF 3144 is a 4-channel, 16-bit, Programmable Resistor Module for Compact RIO.
Each channel is galvanically isolated, making it ideal for sensor simulation.
The 16-bit resolution is non-linear with finer steps at lower resistance values. It could, for example, be used to emulate a PT100 sensor with a range of 40–180Ω/-150–+200°C with a resolution of 0.1°C.
$ 1,760.00
In stock (can be backordered)
Quote request for WF 3144 – Programmable Resistor Module
Downloads, Information & Videos
Downloads
LabVIEW Driver
AC0021-003 Container – VIP file v2.1.1.zip Older versions of this driver might be found HERE
User Manual
AC0021-002 WF3144 User Manual.pdf
Data sheet
AB0005-004 WF 3144 Data Sheet.pdf
Additional Downloads
Mixing WF and NI modules
AB0005-056 AN4 Mixing WF and NI modules.pdf | Example files referenced in the document can be found HERE
Simulation of a temp sensor
AB0005-006 AN1 Simulation of a temp sensor.pdf
Enhanced Mode
AB0005-017 WP1 WF 3144 Enhanced Mode.pdf
FPGA Resource Usage for WF C Series modules
AB0005-104 AN16 FPGA Resource Usage for WF C Series modules.pdf
WF modules and Scan mode
AB0005-041 AN13 WF modules and Scan mode.pdf
PT100 Resistance Thermometer Simulator
AB0005-085 AN9 PT100 Simulator.pdf | Example files referenced in the document can be found HERE
NTC Thermistor Simulator
AB0005-087 AN10 Thermistor Simulator.pdf | Example files referenced in the document can be found HERE
Integrating WF modules with NI VeriStand
AB0005-098 AN14 Integrating WF modules with NI VeriStand.pdf | Code examples can be downloaded HERE
Specifications
– Channels; 4
– Max Voltage; 60 V
– Max Power; 100 mW/channel
– Range; 16 Ω–160 kΩ
– Update Rate; 200 S/s
– Max Error; R < 1 kΩ: 0,1 %
– Max Error; R < 10 kΩ: 1 %
– Max Error; R < 160 kΩ: 10 %
– Enhanced mode: Max Error; 32 Ω < R < 160 kΩ: 0.25 %
Features
– Four independent, galvanically isolated channels
– Entirely solid-state simulation
– High resolution with non-linear scaling
– Wide resistance range
– On-board calibration memory
– LabVIEW driver included
– VeriStand driver available
Application areas
– Resistive sensor simulation;
– Pressure sensors, Thermistors, RTDs etc.
– ATE (Automatic Test Equipment)
– HiL testing (Hardware in the Loop)
– Laboratory testing of electronic control units
– Automated calibration and alignment
– Automate manual controls
Shipping information
– Product Net Weight: 0.17 kg
– Country of Origin: Sweden (SE)
– Harmonized System (HS) / TARIC Code: 8537109199
Support & FAQ
Visit our knowledge base on our Support Portal if you don’t find any answers to your questions here.
General information
Can I use ScanEngine for the module?
ScanEngine access is not directly accessible for Third-Party modules, but it is quite easy to mix WireFlow C Series modules with other NI modules in a system and still access the NI modules in Scan Mode. Please see application note AB0005-056 AN4 Mixing WF and NI modules for a step-by-step guide how to do this.
What kind of connector are used for the module?
The WF 3144 and uses a 10-Pos Plug. You should connect a terminal block for 10-Pos Plug to the module. This terminal block is included together with the module when shipped from WireFlow. If you need some extra plugs you should acquire article 1970045 from Phoenix Contact.
How many FPGA resources does a C series module consume?
The FPGA usage of a specific software and hardware combination is affected by multiple factors such as; FPGA type and size, compilation options, the random starting point for FPGA code placement etc.
Hence, it is impossible to derive an exact figure that defines the FPGA usage of a specific C series module. For customers that are uncertain on whether their application will fit on a specific FPGA with a WireFlow C series module it is recommended to make a test-build. Note that no hardware is needed to make a test build. For more details, please see AB0005-104 AN16 FPGA Resource Usage for WF C Series modules.
Is the WF 3144 module compatible with cDAQ-systems from National Instrument?
No it is not. At the moment only the WF 3132 module works on both CompactDAQ and CompactRIO systems. The WF 3144 is for time being only compatible with the CompactRIO systems, including the expansions chassis for Ethernet, EtherCAT, R Series and MXI-Express. However, National Instruments has released a CompactRIO series that supports NI-DAQmx, called NI-904x (you can find them HERE). On these chassis you can use all of our C Series modules.
Does the module work with cDAQ-systems from National Instrument?
No. The module is only compatible with the CompactRIO chassis, including the expansions chassis for Ethernet, EtherCAT, R Series and MXI-Express. However, National Instruments has released a CompactRIO series that supports NI-DAQmx, called NI-904x (you can find them HERE). On these chassis you can use all of our C Series modules.
How is the WF 3144 Programmable Resistor Module designed?
The module uses an array of real resistors switched with solid state relays to the desired resistance.
Ecu Test Demo
NI Alliance Partner, WireFlow AB, shows a demo that illustrates how a simple Electronic Control.
Get up and running with the WF 3144 Resistor Module
Magnus from WireFlow shows step-by-step how to get up and running with the programmable resistor for the Compact RIO.